LV APFC Panels
LV APFC Panels Supplier
LV APFC Panels
EPCOS offers wide range of automatic switched capacitor panels for Power Factor correction in various configurations for a wide range of applications. The Panels are both Contactor switched and Thyristor switched type.
Daga Switchgears & Electricals PVT. LTD. Low Voltage Automatic Real Time Power Factor Controller Capacitor Panel using Low voltage sturdy Daga Switchgears & Electricals PVT. LTD. capacitor with Thyristor or contactor as a switching devices, Inrush current limiting reactor or harmonics filter reactor.
The greater part of power distribution companies have recommendations that discourage commercial and industrial customers for failing to maintain power factor above a specific threshold (usually above 0.90 value) in order to best maximise the use of available power. Reactive power consumption should be reduced or eliminated, i.e., power factor should be unity. However, the power factor is either lagging or leading due to reactive power drawn by capacitive or inductive loads in the consumer premises. This means that the capacitors (for lagging PF) or reactors (for leading PF) are connected across the system to maintain it within the limit, i.e., for compensating or supplying the required LV APFC Panel. For stable load the fixed LV APFC Panel compensation is required, while for variable load the KVAR requirement also changes as per the load duration cycle, thus in such case the Automatic Power Factor Control Panel is installed.
Features
- Wide choice of capacitors
- High quality reactors with highest linearity
- Appropriate switching devices
- Reducing electricity.
- A decrease in the kVA demand.
- Transformer and cable losses are decreased.
- Impulse operation is prevented by time delay.
- No inrush current, voltage spikes, surges, or harmonics are produced when the capacitor is switched.
- Anti-corrosive coating is painted on as a powder to the panels. • Small design.
- Effective post-purchase assistance.
- State of art controllers
- Thyristor modules for real time power factor correction
- Proven performance of APFC in welding/ unbalanced load
- Expand the generator's loading capacity.
- Because kVA is precisely proportional to current, it significantly reduces hysteresis, eddy current, and I2R losses.
- Enhances electrical equipment performance.
- Dynamic switching that is automated.
- Panels that adhere to all international requirements employ switchgear. IP4XX protects the panels.
- The thermostat as well as exhaust fan keep things cool.
Specification of APFC Panel
- Rated Voltage : 380/ 400 /4 15 /440/ 690 V
- Rated Frequency: 50 / 60 Hz
- Rated Output : 20 -1500 KVAr
- Configuration : Delta / Star floating / Star grounding
- Number of steps : 1-16.
- Step Distribution : Equal / Binary / Unequal
- Series Reactor : 0.2% ,5.67%, 7%,14%
- Reactor winding : Copper/ Al. strip / Al. foil.
- Data logging: Through controller internal memory (select models)
- Communication interface: Optional (RS 232, RS 485, Profibus).
- Switching device : Thyristor/ Capacitor duty contactor
- Panel Type: Standard / Modular / Compartmentalized
- Branch Protection : HRC fuse/ semiconductor fuse / SFU / MCCB
- Capacitors : Resin filled / Gas filled / APP
- Protections : OV / UV / SC / EF / OT /smoke / fire
- Controller : BR 4000 / BR 5000 / BR 6000
- Measuring CT : 1 or 3.
- Power analyzer : Optional.
Special Designs
APFC panels of special design for critical applications can also be offered, such as –
- Individual phase correction as required in residential or commercial establishments.
- Welding type of loads.
APPLICATION
- 40% saving in electricity bill.
- Saving in losses of transformer rating.
- We offers range/ratings of LV Automatic Power Factor Controller Capacitor Panel is as per system or customer requirements with all voltage class.
- Supply quality improves.
- Avoid nuisance tripping for sensitive load in event of harmonics effect.